NON WALKABLE ROOFS - INSULATED ROOF

Non walkable roofs - Insulated roof,

1 Support: Concrete - Wood - Metal

2 Priming coat: Primertec AD (do not use on wood)

3A Vapour barrier: Dimpled faced vapour barrier membrane (do not use on wood)

3B Vapour barrier: PLURA ZEBRA VAPOUR BARRIER

4 Thermal insulating element: Insulating panel (EPS/PUR/PIR/RW)

5 Adhesive element: Millennium One Step™ foamable adhesive foamable adhesive

6 Thermal insulating element: Insulating panel (EPS/PUR/PIR/RW)

7 Adhesive, connecting and sectoring element: Plura Thermo AD V 2,5 mm

8 Double reinforced corner: with membrane BPP P 4 mm > di 250 mm

9A Waterproofing element: Pratiko G200 Mineral

9B Waterproofing element: Pratiko G200 Mineral + Voltaika coating

10A Double reinforced corner: Pratiko G200 Mineral

10B Double reinforced corner:Pratiko G200 Mineral + Voltaika coating

11 Finishing element: Metal flashing expansion joint with mechanical fixings and seal with Pratiko Mastic